Since 1993, municipalities around the world have relied on TrojanUV to produce non-potable reuse water. This water provides a cost-effective, local and sustainable water supply for irrigation, construction uses and industrial processes.
Building on the legacy of TrojanUVFit and our flagship TrojanUVSigna, TrojanUVFocus brings proven Solo Lamp® technology and the ActiClean® sleeve cleaning system to a purpose-built, closed-vessel UV platform. Designed for reliability and ease of maintenance, the TrojanUVFocus incorporates operator feedback gathered over a decade.
Validated to the stringent NWRI standard, the innovative chamber design delivers superior efficiency, lower total installation costs, and fewer required lamps, while still ensuring high performance without compromise.
The revolutionary TrojanUV Solo Lamp combines the best features of both low pressure and medium pressure lamps. The TrojanUVFocus leverages the 1000 Watt Solo Lamp, one of the most powerful amalgam lamps in the world to deliver a high UV dose while maintaining electrical efficiency and a low lamp count.


Thanks to the patented ActiClean sleeve cleaning system, quartz sleeves and intensity sensors are cleaned regularly without disrupting treatment – there’s no need to shut down the UV system or remove lamps for routine cleaning. This dual-action cleaning system uses mechanical wiping in conjunction with a cleaning solution contained within wiper canisters surrounding the quartz sleeves. This provides superior cleaning performance and ensures you minimize downtime and maximize disinfection performance.


The TrojanUVFocus includes a new optimized flow distribution design (patent pending) developed with our world class in-house CFD modelling and mechanical design team. This allows for energy savings through fewer lamps while maintaining high dose in low UVT waters. Once water enters the chamber, it is hydraulically rotated throughout, ensuring all water is thoroughly irradiated. With the decreased energy and equipment costs, the TrojanUVFocus minimizes your operational and capital costs while maximizing overall system performance.


Maintenance is now simpler than ever with the added davit arm on the TrojanUVFocus chamber. Simply drain the water from the chamber, unplug lamps, and remove the end cap with the help of the davit arm – no crane required. This increased serviceability is also enabled by the innovative internal flange which allows for a reduced system size and installation flexibility.


Connected Service with Stream
UV treatment is a critical process step and with proper monitoring and maintenance, can effectively operate for many years without surprises. Here to help support your UV operations is Stream™. Our digital network and toolbox that gives you access to the right information and support when and where you need it.


Model Type | 10L | 14L | 18L |
|---|---|---|---|
Chamber Shape | L Shape | ||
Chamber Size (in) | 24 | 28 | |
Flange Size (in) | 10 | 12 | |
Validated UVT (%) | 30-85 Optimized for 55-70 | ||
Flow Rate (mgd) | 0.19 - 3.5 | 0.19 - 5 | |
Total Suspended Solids (TSS) | < 10ppm | ||
Cleaning system | Automatic ActiClean chemical/mechanical | ||
Lamp Type | TrojanUV Solo Lamp (amalgam) | ||
Lamp Driver | Electronic, high-efficiency (99% power factor) | ||
Input Power Per Lamp | 1000 Watts | ||
Lamp Control | 30 - 100% variable lamp power (0.5% increments) | ||
UV Intensity Sensor | 1 per chamber – with automatic chemical cleaning | ||
Installation Location | Indoors or outdoors | ||
System Control Center | Standard color HMI Available with either Siemens or Allen-Bradley control platforms | ||
Chamber Material | 316 stainless steel | ||
Pressure Rating | PN 10 (150 psi) | ||
SCADA Network Connection | AB Ethernet I/P, ProfiNet, Profibus, Modbus TCP/IP, Modbus RTU RS485 | ||
Panel Material | Painted mild steel, 304 stainless steel, 316 stainless steel | ||
Validation | USEPA and NWRI | ||
Sizing the TrojanUVFocus
TrojanUV offers non-potable reuse systems for flow ranges from 0 to 40 MGD. Each system is optimized and sized for an ideal flow range to best serve your water quality objectives.
Flow Range (MGD) | TrojanUVFit | TrojanUVFocus | TrojanUVFlex |
|---|---|---|---|
0 – 1 | ⚫ | ◗ | |
1 – 5 |
Flow ranges normalized for 65% UVT and target MS2 RED of 80mJ/cm2
TrojanUVFocus Brochure
Building on the legacy of flagship TrojanUV municipal water disinfection systems, the TrojanUVFocus brings proven UV technology and long-term reliability to a closed-vessel UV platform engineered specifically for municipal non-potable reuse applications.

Stream App Brochure
The Stream™ App provides a personal view into your UV system with easy to understand insights. It allows you to quickly view the status of your UV system, receive instant alarm notifications, and access step-by-step instructions for resolving common UV issues.
Stream App for AOP Demonstration System
Stream provides a real-time view into your UV system, giving you secure access to performance data anywhere you have a wireless internet connection.
◗
⚫ |
◗ |
5 - 40 | ◗ | ⚫ |


The latest in non-potable reuse UV disinfection